Steritest™ NEO Accessories

Recommended Products
-
203996-10MG Sigma-Aldrich N-Butyldeoxynojirimycin, Hydrochloride - CAS 72599-27-0 - Calbiochem -
MVHABG124 Millipore Microfil V,100mL,混合纤维素酯,0.45µm 黑色网格 -
807582 Sigma-Aldrich 庚酸 -
2380 Sigma-Aldrich Creatine Phosphate, Disodium Salt - CAS 19333-65-4 - Calbiochem -
1065735000 SAFC 磷酸氢二钠 -
1460030120 Millipore SDA w. Cm acc. EP - LI -
CVDI73TPS Millipore Durapore® CVDI Cartridge Filter 30 in. 0.2 uM Code 7 Silicone -
KHGEG2THH1 Millipore Opticap® Gamma Compatible XLT 20 Millipore Express® SHC 0.5/0.2 µm 5/8 in. HB
概述
规格
订货信息
Documentation
参考
参考概述 | 公共医疗ID |
---|---|
The Effect of Vaporous Phase Hydrogen Peroxide on Sterility Test Devices Roche Lentine, Kerry and Robert J. Keller; Pharmaceutical Technology Europe, February 2003: 31- 42. Pharmaceutical Technology Europe, February 2003: 31- 42. 2003 | The Effect of Vaporous Phase Hydrogen Peroxide on Sterility Test Devices
![]() |
相关产品和应用
产品族
![]()
Steritest™ NEO Devices for Products Without Antimicrobial AgentsBlue canister base. Mixed esters of cellulose membrane. This membrane provides an optimal filtration flow rate for standard products. Canisters material: SAN (Styrene-Acrylo Nitrile)详细了解 >> |
![]()
Steritest™ NEO Devices for Antibiotics and Products with Antimicrobial ActivityRed canister base with specific drain design. Low binding PVDF Durapore® membrane. This optimizes the rinsing of products that inhibit microbial growth. Canisters material: SAN详细了解 >> |
![]()
Steritest™ NEO Device for products requiring increased Chemical CompatibilityGreen canister base with specific drain design. Low binding PVDF Durapore® membrane optimize the rinsing of products that inhibit microbial growth. Canisters material: polyamide polymer.详细了解 >> |
![]()
Steritest™ EZ Devices Double-PackedIncrease your test method reliability with our gamma sterilized sterility testing device详细了解 >> |
![]()
Sterility TestingCountless configurations详细了解 >> |
相关产品,按下列排序: Application Facete
Sterility Testing |
相关产品,按下列排序: Brand Facete
Steridilutor® |
Steritest™ |
种类
Industrial Microbiology > Sterility Testing > Membrane Filtration Sterility Test |
Sample Preparation and Dilution
- Tubing and needle assembly to dissolve powders, for dilution and pool products in vials
- To be used for difficult to dissolve powders, dilution and pooling of viscous products in vials as well as antibiotics (to reduce the contact time with the filtration membrane)
- The expansion chamber vents residual vacuum or pressure from the vials without after-drip or contamination risk
- Small diameter double needle connects test product to diluent
- Diluted product subsequently filtered with suitable Steritest™ NEO canisters
Steridilutor® NEO devices for liquids and soluble powders in vials - without expansion chamber TZV000010
Steridilutor® NEO devices for liquids and soluble powders in vials - with expansion chamber TZVC00010
Liquid Transfer
- Tubing and needle assembly for transfer of liquids from ampoules or vials to a diluent vial with septum
- Diluted products subsequently tested with suitable Steritest™ NEO canister
Steridilutor® NEO devices for liquid transfer TZA000010
Sterile Vent Needles
- Single needle vented with PTFE 0.22 μm membrane
- For venting glass vials with septa and rigid plastic vials
- For venting of media bottles during the direct inoculation method
- For sterility and growth promotion qualification of media batches