About This Item
Quality Level
species reactivity
human
manufacturer/tradename
Milliplex®
assay range
accuracy: 102%
(Haptoglobin)
accuracy: 109%
(AGP)
accuracy: 113%
(Platelet Factor-4)
accuracy: 117%
(Adipsin)
standard curve range: 0.004-15 ng/mL
(L-Selectin & SAP)
standard curve range: 0.012-50 ng/mL
(CRP)
standard curve range: 0.037-150 ng/mL
(PF4)
standard curve range: 0.061-250 ng/mL
(HPTGN)
standard curve range: 0.098-400 ng/mL
(AGP & Adipsin)
standard curve range: 0.244-1,000 ng/mL
(Fetuin A & vWF)
standard curve range: 0.488-2,000 ng/mL
(A2M)
technique(s)
multiplexing: suitable
detection method
fluorometric (Luminex® xMAP® technology)
shipped in
wet ice
General description
MILLIPLEX® Human Cardiovascular Disease (CVD) Panel 3 (Acute Phase) is a 10-plex kit to be used for the simultaneous quantification of any or all of the following analytes in human serum, plasma or tissue/cell lysate and culture supernatant samples: Adipsin, α-1-Acid-Glycoprotein (AGP), α-2-Macroglobulin (A2M), C Reactive Protein (CRP), Fetuin A, Fibrinogen, L-Selectin, Serum Amyloid P (SAP), Haptoglobin, and Platelet Factor-4 (PF4). (Please note: Fibrinogen is not detectable in serum.) This kit uses a 96-well format, contains a lyophilized standard cocktail, two internal assay quality controls and can measure up to 38 samples in duplicate.
The Luminex® xMAP® platform uses a magnetic bead immunoassay format for ideal speed and sensitivity to quantitate multiple analytes simultaneously, dramatically improving productivity while conserving valuable sample volume.
Panel Type: Cardiovascular
Application
- Analytes: α-1 Acid Glycoprotein (AGP), α-2-Macroglobulin (A2M), Adipsin (Factor D), C Reactive Protein (CRP), Fetuin A, Fibrinogen, Haptoglobin, sL-Selectin, Platelet Factor-4 (PF4/CXCL4), Serum Amyloid P (SAP)
- Recommended Sample Type: Human serum, plasma, cell/tissue culture supernatants and lysates
- Recommended Sample Dilution: 25 μL per well of 1:40,000 diluted serum or plasma; tissue/cell culture samples may require dilution in appropriate control medium
- NOTE: Fibrinogen is not detectable in serum
- Assay Run Time: Overnight (16-18 hours) at 2-8°C or 2 hours at room temperature (20-25 °C)
- Research Category: Cardiovascular Disease
- Research Subcategory: Metabolic Disorders
Features and Benefits
Other Notes
Legal Information
Signal Word
Danger
Hazard Statements
Precautionary Statements
Hazard Classifications
Acute Tox. 3 Dermal - Acute Tox. 4 Inhalation - Acute Tox. 4 Oral - Aquatic Chronic 2 - Eye Irrit. 2 - Skin Irrit. 2 - Skin Sens. 1 - STOT SE 3
Target Organs
Respiratory system
Storage Class Code
6.1C - Combustible acute toxic Cat.3 / toxic compounds or compounds which causing chronic effects
Certificates of Analysis (COA)
Search for Certificates of Analysis (COA) by entering the products Lot/Batch Number. Lot and Batch Numbers can be found on a product’s label following the words ‘Lot’ or ‘Batch’.
Already Own This Product?
Find documentation for the products that you have recently purchased in the Document Library.
Global Trade Item Number
| SKU | GTIN |
|---|---|
| HCVD3MAG-67K-01 | 04053252798900 |
| HCVD3MAG-67K-03 | 04053252798924 |
| HCVD3MAG-67K-02 | 04053252798917 |
| HCVD3MAG-67K-04 | 04053252798931 |
| HCVD3MAG-67K-05 | 04053252798948 |
| HCVD3MAG-67K-08 | 04053252798979 |
| HCVD3MAG-67K-09 | 04053252798986 |
| HCVD3MAG-67K-06 | 04053252798955 |
| HCVD3MAG-67K-07 | 04053252798962 |
| HCVD3MAG-67K-10 | 04053252799495 |
Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.
Contact Technical Service