Select a Size
About This Item
InChI
1S/K.H2O/h;1H2/q+1;/p-1
SMILES string
[OH-].[K+]
InChI key
KWYUFKZDYYNOTN-UHFFFAOYSA-M
Quality Level
vapor pressure
1 mmHg ( 719 °C)
product line
EMSURE®
assay
≥85.0% KOH basis (acidimetric)
form
solid
potency
333 mg/kg LD50, oral (Rat)
pH
14 (20 °C, 56 g/L in H2O)
mp
361 °C (lit.)
solubility
1130 g/L
anion traces
carbonate (K2CO3): ≤1.0%, chloride (Cl-): ≤0.005%, phosphate (PO43-): ≤0.0005%, silicate (as SiO2): ≤0.005%, sulfate (SO42-): ≤0.0005%
cation traces
Al: ≤0.001%, Ca: ≤0.001%, Cu: ≤0.0002%, Fe: ≤0.0005%, N: ≤0.0005%, Na: ≤0.5%, Ni: ≤0.0005%, Pb: ≤0.0005%, Zn: ≤0.0025%, heavy metals (as Pb): ≤0.0005%
storage temp.
2-30°C
grade
reagent grade
agency
suitable for SM 5210
Looking for similar products? Visit Product Comparison Guide
Related Categories
Analysis Note
Carbonate (as K₂CO₃): ≤ 1.0 %
Chloride (Cl): ≤ 0.005 %
Phosphate (PO₄): ≤ 0.0005 %
Silicate (SiO₂): ≤ 0.005 %
Sulfate (SO₄): ≤ 0.0005 %
Total nitrogen (N): ≤ 0.0005 %
Heavy metals (as Pb): ≤ 0.0005 %
Al (Aluminium): ≤ 0.001 %
Ca (Calcium): ≤ 0.001 %
Cu (Copper): ≤ 0.0002 %
Fe (Iron): ≤ 0.0005 %
Na (Sodium): ≤ 0.5 %
Ni (Nickel): ≤ 0.0005 %
Pb (Lead): ≤ 0.0005 %
Zn (Zinc): ≤ 0.0025 %
Legal Information
Application
- To precipitate perchlorate ions after the addition of perchloric acid during the extraction of intracellular metabolites from yeast. It is also utilized to adjust the pH of the solution, ensuring optimal conditions for subsequent analysis.
- In corrosion testing of anodized aluminium alloys to evaluate mass loss and corrosion resistance of the anodic layer.
- To basify reaction mixtures, facilitating the derivatization needed for gas chromatography-mass spectrometry (GC-MS) analysis in the identification of metabolic precursors.
signalword
Danger
hcodes
Hazard Classifications
Acute Tox. 4 Oral - Eye Dam. 1 - Met. Corr. 1 - Skin Corr. 1A
Storage Class
8B - Non-combustible corrosive hazardous materials
wgk
WGK 1
flash_point_f
Not applicable
flash_point_c
Not applicable
Regulatory Listings
Regulatory Listings are mainly provided for chemical products. Only limited information can be provided here for non-chemical products. No entry means none of the components are listed. It is the user’s obligation to ensure the safe and legal use of the product.
Substances Subject to be Indicated Names
ishl_indicated
Substances Subject to be Notified Names
ishl_notified
1050330524: + 1050330000: + 1050330500: + 1050338889: + 1050331008: + 1050339025: + IN2RCMP105033: + 1050331000: + 1050339050: + 1050335000:
jan
Certificates of Analysis (COA)
Search for Certificates of Analysis (COA) by entering the products Lot/Batch Number. Lot and Batch Numbers can be found on a product’s label following the words ‘Lot’ or ‘Batch’.
Already Own This Product?
Find documentation for the products that you have recently purchased in the Document Library.
Articles
Compare PAH determination in olive oil: traditional GB 5009.265-2021 method vs. faster, simpler SPE with Supelclean™ EZ-POP NP; both meet criteria.
Related Content
This page is intended to make it easier to find the consumables you need based on the analytical method you’re using. Methods included on this page come from the EPA, Standard Methods and ASTM.
Global Trade Item Number
| SKU | GTIN |
|---|---|
| 1.05033.9025 | 04022536531878 |
| 1.05033.9050 | 04022536059655 |
| 1.05033.0500 | 04022536059594 |
| 1.05033.1000 | 04022536059617 |
| 1.05033.5000 | 04022536059631 |
Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.
Contact Technical Service