コンテンツへスキップ
Merck

03-0187-00

Millipore

SMC® Human MCP-1 High Sensitivity Immunoassay Kit

別名:

MCP 1 immunoassay kit, MCP-1 Single Molecule Counting Kit, MCP-1 ultra-sensitive immunoassay, Monocyte Chemoattractant Protein-1 immunoassay kit

ログイン組織・契約価格を表示する

サイズを選択してください


この商品について

UNSPSCコード:
12161503
NACRES:
NA.84
テクニカルサービス
お困りのことがあれば、経験豊富なテクニカルサービスチームがお客様をサポートします。
お手伝いします
テクニカルサービス
お困りのことがあれば、経験豊富なテクニカルサービスチームがお客様をサポートします。
お手伝いします


詳細

0.08-0.31 pg/mL, refer to CoA for lot-specific LLOQ

メーカー/製品名

SMC®

assay range

sensitivity: 0.15 pg/mL
(Lower Limit of Quantification)

inter-assay cv: 4%
intra-assay cv: 5%
(five normal plasma samples run in triplicate by 3 different operators on 3 different days.)

テクニック

single molecule counting: suitable

保管温度

2-8°C

アプリケーション

The sensitivity of the Single Molecule Counting (SMC®) technology gives the SMC® Human MCP-1 High Sensitivity Immunoassay Kit unparalleled performance in the quantification of MCP-1 in human serum and plasma.

This new streamline kit has the following features including:
  • Improved options for sample prep and incubation
  • Lyophilization of the standard provides the kit at one storage condition
  • Removal of a plate transfer step
  • Increased reagent volumes to accommodate automation
  • Validated to run on both SMCxPRO® and Erenna


Research Category:

Inflammation & Immunology

Research Sub-Category:
  • Inflammatory Disease
  • Immune Response
  • Autoimmune disease

生物化学的/生理学的作用

Species Reactivity:
Specificity to the following species analytes were tested with the following results:
Rat – Not cross-reactive
Mouse – Not cross-reactive
Canine – Not cross-reactive

Cross Reactivity:
Cross-reactivity to the following analytes were tested with the following results:
MCP-2 – Not cross-reactive
MCP-3 – Not cross-reactive

Accuracy:
  • Minimum of 5 serum samples spiked with average recovery of 104% with a range of 92-115%
  • Minimum of 5 plasma samples spiked with average recovery of 101% with a range of 80-123%

包装

96 well assay

その他情報

  • Assay Buffer
  • MCP-1 Coated Beads
  • Standard Diluent
  • MCP-1 Detection Antibody
  • MCP-1 Standard
  • 10X Wash Buffer
  • Buffer D
  • Elution Buffer B

法的情報

SMC is a registered trademark of Singulex
SMCxPRO is a registered trademark of Merck KGaA, Darmstadt, Germany

免責事項

Unless otherwise stated in our catalog or other company documentation accompanying the product(s), our products are intended for research use only and are not to be used for any other purpose, which includes but is not limited to, unauthorized commercial uses, in vitro diagnostic uses, ex vivo or in vivo therapeutic uses or any type of consumption or application to humans or animals.

ピクトグラム

Skull and crossbonesHealth hazard

シグナルワード

Danger

危険有害性の分類

Acute Tox. 3 Dermal - Acute Tox. 4 Inhalation - Acute Tox. 4 Oral - Aquatic Chronic 3 - Eye Irrit. 2 - Repr. 1B

保管分類コード

6.1C - Combustible acute toxic Cat.3 / toxic compounds or compounds which causing chronic effects


適用法令

試験研究用途を考慮した関連法令を主に挙げております。化学物質以外については、一部の情報のみ提供しています。 製品を安全かつ合法的に使用することは、使用者の義務です。最新情報により修正される場合があります。WEBの反映には時間を要することがあるため、適宜SDSをご参照ください。

毒物及び劇物取締法

キットコンポーネントの情報を参照してください

PRTR

キットコンポーネントの情報を参照してください

消防法

キットコンポーネントの情報を参照してください

労働安全衛生法名称等を表示すべき危険物及び有害物

キットコンポーネントの情報を参照してください

労働安全衛生法名称等を通知すべき危険物及び有害物

キットコンポーネントの情報を参照してください

カルタヘナ法

キットコンポーネントの情報を参照してください

Jan Code

キットコンポーネントの情報を参照してください



試験成績書(COA)

製品のロット番号・バッチ番号を入力して、試験成績書(COA) を検索できます。ロット番号・バッチ番号は、製品ラベルに「Lot」または「Batch」に続いて記載されています。

以前この製品を購入いただいたことがある場合

文書ライブラリで、最近購入した製品の文書を検索できます。

文書ライブラリにアクセスする


関連コンテンツ

1分子カウント(Single Molecule Counting、SMC™)技術を用いた高感度イムノアッセイにより、免疫学研究を推進し、インターフェロン、インターロイキン、免疫グロブリンを正確に特性評価する方法を説明します。

See how you can enhance your immunology research through the power of high sensitivity immunoassays by harnessing Single Molecule Counting (SMC®) technology to precisely characterize interferons, interleukins, and immunoglobins.