Select a Size
About This Item
Quality Level
usage
kit sufficient for 96 wells
species reactivity
human
manufacturer/tradename
SMC®
assay range
sensitivity: 5.86 pg/mL
(lower limit of quantification)
technique(s)
single molecule counting: suitable
input
plasma (K2 EDTA)
cerebrospinal fluid (CSF)
UniProt accession no.
compatibility
for use with FemtoQuest™ and SMCxPRO® instruments
shipped in
wet ice
General description
Aβ1-40 plays a significant role in the pathophysiology of Alzheimer′s disease. Elevated levels of Aβ1-40 in the brain can contribute to neuroinflammation and neuronal damage, disrupting cell signaling and promoting the formation of amyloid plaques. These plaques are characteristic of AD and are believed to trigger a cascade of neurodegenerative processes, leading to cognitive decline and other symptoms associated with the disease. Understanding the function and implications of Aβ1-40 is essential for developing effective diagnostic tools and therapeutic strategies aimed at mitigating its harmful effects in neurodegenerative conditions.
Application
Biochem/physiol Actions
Features and Benefits
- Exceptional Sensitivity: Detects Amyloid Beta 1-40 at femtogram levels, significantly outperforming conventional ELISA methods.
- Wider Dynamic Range: Minimizes background interference to deliver clearer signals and improved assay reliability.
- Optimized Workflow Efficiency: Automation-compatible reagents streamline lab processes and reduce manual intervention.
- Experienced Technical Support: Supported by skilled field scientists and technical teams with expertise in SMC® assays.
Packaging
Analysis Note
- Sensitivity: LLOQ 5,860 fg/mL* (SMCxPRO® instrument
- Standard Curve Range: 340-350,000 fg/mL
- Intra-assay CV: <15%
- Inter-assay CV: <10%
- Linearity: Plasma: 104% CSF: 109%
- Recovery: Plasma 110% CSF: 100%
*Indicative LLOQ created from average of 14 independent in house runs, where >80% met same value defined with CV & Recovery +/- 20%. Refer to CoA for lot specific performance.
Legal Information
Disclaimer
Signal Word
Danger
Hazard Statements
Precautionary Statements
Hazard Classifications
Acute Tox. 3 Dermal - Acute Tox. 4 Inhalation - Acute Tox. 4 Oral - Aquatic Chronic 3 - Eye Irrit. 2 - Repr. 1B
Storage Class Code
6.1C - Combustible acute toxic Cat.3 / toxic compounds or compounds which causing chronic effects
Regulatory Listings
Regulatory Listings are mainly provided for chemical products. Only limited information can be provided here for non-chemical products. No entry means none of the components are listed. It is the user’s obligation to ensure the safe and legal use of the product.
PDSCL
Please refer to KIT Component information
PRTR
Please refer to KIT Component information
FSL
Please refer to KIT Component information
ISHL Indicated Name
Please refer to KIT Component information
ISHL Notified Names
Please refer to KIT Component information
Cartagena Act
Please refer to KIT Component information
JAN Code
キットコンポーネントの情報を参照してください
Certificates of Analysis (COA)
Search for Certificates of Analysis (COA) by entering the products Lot/Batch Number. Lot and Batch Numbers can be found on a product’s label following the words ‘Lot’ or ‘Batch’.
Already Own This Product?
Find documentation for the products that you have recently purchased in the Document Library.
Protocols
To determine protein content, the Warburg-Christian method refers to measuring protein samples at 280 nm using a spectrophotometer.
Related Content
さまざまなサンプルのタンパク質濃度を正確に測定するためのタンパク質定量法、試薬、イムノアッセイ技術。
Protein quantification methods, reagents, and immunoassay technology for accurately measuring the protein concentrations in a variety of samples.
神経免疫学、神経炎症サイトカイン、神経変性疾患バイオマーカーの研究のためのイムノアッセイ
神経科学研究において、強力なSMCxPRO®検出プラットフォームと1分子カウント(SMC®)高感度イムノアッセイキットを使用することにより、健常から疾患状態にいたるまで、主要な神経タンパク質アナライトを高精度に測定します。NF-L、GFAP、タウタンパク質、アミロイドβなどの神経科学バイオマーカーを解析してください。
Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.
Contact Technical Service