製品名
水酸化ナトリウム 溶液, c(NaOH) = 2 mol/l (2 N), Titripur®
InChI
1S/Na.H2O/h;1H2/q+1;/p-1
SMILES string
[OH-].[Na+]
InChI key
HEMHJVSKTPXQMS-UHFFFAOYSA-M
vapor pressure
3 mmHg ( 37 °C)
product line
Titripur®
form
liquid
quality
Analyzed in our ISO 17025 accredited QC lab
reaction suitability
reaction type: Acid-base reactions
concentration
2 M
technique(s)
titration: suitable
pH
13.8 (20 °C in H2O)
density
1.09 g/cm3 at 20 °C
storage temp.
15-25°C
Quality Level
類似した製品をお探しですか? 訪問 製品比較ガイド
関連するカテゴリー
Analysis Note
Amount-of-substance concentration 1.990 - 2.010 mol/L
Measurement uncertainty ± 0.006 mol/L
Traceability NIST SRM
The concentration is determined by volumetric titration and refers to 20°C.
The amount-of-substance concentration of this volumetric solution is traceable to a primary standard reference material (SRM) from the National Institute of Standards and Technology, Gaithersburg, USA (NIST SRM 84 potassium hydrogen phthalate) by means of volumetric standard potassium hydrogen phthalate (article number 1.02400), certified reference material according to ISO 17034, analyzed by our accredited calibration laboratory of Merck KGaA, Darmstadt, Germany according to DIN EN ISO/IEC 17025. The uncertainty is expressed as expanded measurement uncertainty with a coverage factor k=2 covering a confidence level of 95%.
Note: The titer is a correction factor to correct for variations of the volumetric solution, the titration equipment, the temperature and other laboratory conditions. For correct titration results it is recommended to determine a titer with the laboratory specific equipment and under laboratory specific conditions directly after opening a new bottle and at regular time intervals.
Application
- Transitory alkali exposure on meibomian gland orifices induces meibomian gland dysfunction.: This research utilizes sodium hydroxide solution to create a model of meibomian gland dysfunction by transiently exposing gland orifices to alkali, providing insights into the pathophysiology of dry eye diseases and potential therapeutic approaches (Bu J et al., 2023).
- Radionuclides′ Recovery from Seawater Using FIC and FIC A Sorbents.: This study utilizes sodium hydroxide solution in the processing of innovative sorbents designed for the efficient recovery of radionuclides from seawater, highlighting its role in environmental protection and nuclear waste management (Bezhin NA et al., 2023).
- Synthesis of Chitosan-Silver Nanocomposite and Its Evaluation as an Antibacterial Coating for Mobile Phone Glass Protectors.: Demonstrating the application of sodium hydroxide solution in the synthesis of chitosan-silver nanocomposites, this study explores their potential as antibacterial coatings for mobile phone protectors, contributing to public health by reducing pathogen transmission on high-touch surfaces (Canama GJC et al., 2023).
Features and Benefits
This volumetric solution is analyzed by our calibration laboratory D-K-15185-01-00 which is accredited according to DIN EN ISO/IEC 17025 for analysis of amount-of-substance concentrations in volumetric solutions by DAkkS (Deutsche Akkreditierungsstelle - German National Accreditation Body). The accreditation certificate can be found at www.sigmaaldrich.com/ISO17025.
Packaging
Legal Information
signalword
Danger
hcodes
Hazard Classifications
Eye Dam. 1 - Met. Corr. 1 - Skin Corr. 1A
保管分類
8B - Non-combustible, corrosive hazardous materials
wgk
WGK 1
flash_point_f
Not applicable
flash_point_c
Not applicable
試験成績書(COA)
製品のロット番号・バッチ番号を入力して、試験成績書(COA) を検索できます。ロット番号・バッチ番号は、製品ラベルに「Lot」または「Batch」に続いて記載されています。
プロトコル
Preparation of a standard solution for Chlorine dioxide acc. to DIN EN ISO 7393
Preparation of a standard solution for free Chlorine according to DIN EN ISO 7393
DIN EN ISO 7393に従った二酸化塩素の標準溶液の調製
DIN EN ISO 7393に従った遊離塩素用標準溶液の調製