コンテンツへスキップ
Merck

HSTCMAG-28SK

MILLIPLEX® Human High Sensitivity T Cell Panel

Configurable 96-well Human High Sensitivity T Cell 21-Plex Panel

別名:

Human high-sensitivity cytokine multiplex kit, Luminex® human high-sensitivity cytokine immunoassay, Millipore human high-sensitivity cytokine panel

ログインで組織・契約価格をご覧ください。

この商品について

UNSPSC Code:
12161503
NACRES:
NA.47
eCl@ss:
32161000


製品名

MILLIPLEX® Human High Sensitivity T Cell Panel,

Quality Level

description

Configurable 96-well Human High Sensitivity T Cell 21-Plex Panel

species reactivity

human

packaging

pkg of 1 ea

manufacturer/tradename

Milliplex®

technique(s)

multiplexing: suitable

input

serum
plasma
cell culture supernatant(s)

assay range

accuracy: 98-107%, sensitivity: 0.11-8.17 pg/mL
(Overnight Incubation minDC), standard curve range: 0.18-750 pg/mL
(IL-6), standard curve range: 0.24-1,000 pg/mL
(IL-13), standard curve range: 0.24-1,000 pg/mL
(IL-21), standard curve range: 0.31-1,250 pg/mL
(IL-8), standard curve range: 0.31-1,250 pg/mL
(MIP-1α), standard curve range: 0.37-1,500 pg/mL
(IL-7), standard curve range: 0.45-1,750 pg/mL
(TNFα), standard curve range: 0.49-2,000 pg/mL
(IL-1β), standard curve range: 0.49-2,000 pg/mL
(IL-12 (p70)), standard curve range: 0.49-2,000 pg/mL
(IL-2), standard curve range: 0.49-2,000 pg/mL
(IL-5), standard curve range: 0.61-2,500 pg/mL
(IFNγ), standard curve range: 0.61-2,500 pg/mL
(MIP-3α), standard curve range: 0.73-3,000 pg/mL
(IL-17A), standard curve range: 0.92-3,750 pg/mL
(MIP-1β), standard curve range: 1.22-5,000 pg/mL
(GM-CSF), standard curve range: 1.46-6,000 pg/mL
(IL-10), standard curve range: 1.46-6,000 pg/mL
(ITAC), standard curve range: 1.83-7,500 pg/mL
(IL-4), standard curve range: 18.3-75,000 pg/mL
(Fractalkine), standard curve range: 7.93-32,500 pg/mL
(IL-23), inter-assay cv: <15%
intra-assay cv: <10%

detection method

fluorometric (Luminex® xMAP® technology)

shipped in

wet ice

storage temp.

2-8°C

General description

Cytokines are immunomodulatory polypeptides that play key roles in both adaptive and innate immune responses. One of the regulatory mechanisms of the immune system, cytokines act at the recognition, activation, or effector phases of an immune response, modulating the development and functional activities of the subtypes of T cells, B cells and myeloid cells. Consequently, research involving cytokines plays a significant role in achieving a deeper understanding of the immune system and its multi-faceted response to most antigens, especially those responses that make up the inflammatory process. Low levels of inflammation are involved in many sub-clinical disease states, such as autoimmune disease, cardiovascular disease, diabetes, neurological disorders, and cancer. Measuring picogram levels of cytokines, therefore, is critical for understanding the pathogenesis of these diseases.

Application

MILLIPLEX® Qualified assays undergo rigorous assay development, verification, and Quality Control testing to achieve optimal performance. Simultaneously analyze up to 21 analytes in human serum, plasma, and cell culture supernatants.

Analytes included: Fractalkine, GM-CSF, IFNγ, IL-1β, IL-2, IL-4, IL-5, IL-6, IL-7, IL-8, IL-10, IL-12 (p70), IL-13, IL-17A, IL-21, IL-23, I-TAC, MIP-1α, MIP-1β, MIP-3α, TNF-α

Assay Characteristics: Refer to kit protocol for assay cross-reactivity, sensitivity, precision, and accuracy.

Features and Benefits

  • High-Sensitivity Detection: Enables the detection of low-abundance T cell cytokines, providing critical insights into subtle immune responses and enhancing understanding of disease mechanisms.
  • Simultaneous Quantification of Multiple Analytes: Capable of measuring a variety of T cell-related cytokines and chemokines in a single assay run, including IL-1β, IL-2, IL-6, IL-10, TNFα, and others, saving time and resources.
  • Versatile Sample Compatibility: Offers flexibility in sample types, making the assay applicable to a wide range of research settings and experimental designs.
  • Enhanced Understanding of Immune Responses: Contributes to a deeper understanding of the immune system′s complex interactions, particularly in the context of inflammatory diseases and other clinical conditions.
  • Cardiovascular Risk Profiling: Analyze IFN-γ and MIP-1α, associated with atherosclerotic plaque instability to identify biomarkers for cardiovascular event prediction or therapeutic monitoring.
  • Subpanel Flexibility: Select subsets of analytes (e.g., IL-2, IL-4, IL-5) for focused hypotheses, reducing costs and streamline workflows for targeted immune monitoring.

Legal Information

MILLIPLEX is a registered trademark of Merck KGaA, Darmstadt, Germany
xMAP is a registered trademark of Luminex Corp
Luminex is a registered trademark of Luminex Corporation

Disclaimer

For research use only. Not for use in diagnostic procedures.

Label License/Sticker for Assay Product:

By opening the packaging containing this Assay Product (which contains fluorescently labeled microsphere beads authorized by Luminex Corporation) or using this Assay Product in any manner, you are consenting and agreeing to be bound by the End User Terms and Conditions and the End User License Agreement available at http://support.diasorin.com/end-user-terms-and-conditions/. If you do not agree to all of the terms and conditions, you must promptly return this Assay Product for a full refund prior to using it in any manner.


Still not finding the right product?


signalword

Danger

target_organs

Respiratory Tract

保管分類

10 - Combustible liquids

Hazard Classifications

Acute Tox. 4 Dermal - Acute Tox. 4 Inhalation - Acute Tox. 4 Oral - Aquatic Chronic 2 - Eye Dam. 1 - Skin Irrit. 2 - Skin Sens. 1 - STOT RE 2

wgk

WGK 3


適用法令

試験研究用途を考慮した関連法令を主に挙げております。化学物質以外については、一部の情報のみ提供しています。 製品を安全かつ合法的に使用することは、使用者の義務です。最新情報により修正される場合があります。WEBの反映には時間を要することがあるため、適宜SDSをご参照ください。

Please refer to KIT Component information

pdsc

Please refer to KIT Component information

prtr

Please refer to KIT Component information

fsl

Please refer to KIT Component information

ishl_indicated

Please refer to KIT Component information

ishl_notified

Please refer to KIT Component information

cart

キットコンポーネントの情報を参照してください

jan



試験成績書(COA)

製品のロット番号・バッチ番号を入力して、試験成績書(COA) を検索できます。ロット番号・バッチ番号は、製品ラベルに「Lot」または「Batch」に続いて記載されています。

以前この製品を購入いただいたことがある場合

文書ライブラリで、最近購入した製品の文書を検索できます。

文書ライブラリにアクセスする


関連コンテンツ

MILLIPLEX®アッセイのような免疫学マルチプレックスアッセイにより、研究者は多くの免疫バイオマーカーを同時に測定することで、時間とリソースを節約することができます。これは、多くのアナライトが異なる経路で役割を果たす免疫学研究にとって、特に重要なことです。

Immunology multiplex assays, like MILLIPLEX® assays, allow researchers to investigate more immune biomarkers simultaneously, saving time and resources.

すべての関連コンテンツを見る

Yu-Fei Gao et al.
International journal of ophthalmology, 12(11), 1708-1713 (2019-11-20)
To compare the anti-inflammatory effects of intense pulsed light (IPL) with tobramycin/dexamethasone plus warm compress through clinical signs and cytokines in tears. Eighty-two patients with dry eye disease (DED) associated meibomian gland dysfunction (MGD) were divided into two groups. Group
Bruna M Ascoli et al.
International journal of bipolar disorders, 7(1), 13-13 (2019-06-04)
Innate immune system dysfunction has been recognized as an important element in the pathophysiology of bipolar disorder (BD). We aimed to investigate whether there are differences in the response of macrophages derived from patients in the early stages and late
B Karshikoff et al.
Brain, behavior, and immunity, 57, 38-46 (2016-04-09)
Low-grade systemic inflammation has been implicated in chronic pain, as well as in comorbid diseases like depression and fatigue. We have previously shown that women's pain perception and regulation is more affected by systemic inflammation than that of men. Here