コンテンツへスキップ
Merck
  • Mass spectrometric behavior of anabolic androgenic steroids using gas chromatography coupled to atmospheric pressure chemical ionization source. Part I: ionization.

Mass spectrometric behavior of anabolic androgenic steroids using gas chromatography coupled to atmospheric pressure chemical ionization source. Part I: ionization.

Journal of mass spectrometry : JMS (2014-06-11)
M Raro, T Portolés, J V Sancho, E Pitarch, F Hernández, J Marcos, R Ventura, C Gómez, J Segura, O J Pozo
要旨

The detection of anabolic androgenic steroids (AAS) is one of the most important topics in doping control analysis. Gas chromatography coupled to (tandem) mass spectrometry (GC-MS(/MS)) with electron ionization and liquid chromatography coupled to tandem mass spectrometry have been traditionally applied for this purpose. However, both approaches still have important limitations, and, therefore, detection of all AAS is currently afforded by the combination of these strategies. Alternative ionization techniques can minimize these drawbacks and help in the implementation of a single method for the detection of AAS. In the present work, a new atmospheric pressure chemical ionization (APCI) source commercialized for gas chromatography coupled to a quadrupole time-of-flight analyzer has been tested to evaluate the ionization of 60 model AAS. Underivatized and trimethylsylil (TMS)-derivatized compounds have been investigated. The use of GC-APCI-MS allowed for the ionization of all AAS assayed irrespective of their structure. The presence of water in the source as modifier promoted the formation of protonated molecules ([M+H](+)), becoming the base peak of the spectrum for the majority of studied compounds. Under these conditions, [M+H](+), [M+H-H2O](+) and [M+H-2·H2O](+) for underivatized AAS and [M+H](+), [M+H-TMSOH](+) and [M+H-2·TMSOH](+) for TMS-derivatized AAS were observed as main ions in the spectra. The formed ions preserve the intact steroid skeleton, and, therefore, they might be used as specific precursors in MS/MS-based methods. Additionally, a relationship between the relative abundance of these ions and the AAS structure has been established. This relationship might be useful in the structural elucidation of unknown metabolites.

材料
製品番号
ブランド
製品内容

Sigma-Aldrich
2-メルカプトエタノール, Molecular Biology, suitable for electrophoresis, suitable for cell culture, BioReagent, 99% (GC/titration)
Sigma-Aldrich
2-メルカプトエタノール, ≥99.0%
Sigma-Aldrich
無水酢酸, ReagentPlus®, ≥99%
Sigma-Aldrich
2-メルカプトエタノール, BioUltra, Molecular Biology, ≥99.0% (GC)
Sigma-Aldrich
無水酢酸, puriss. p.a., ACS reagent, reag. ISO, reag. Ph. Eur., ≥99% (GC)
Sigma-Aldrich
無水酢酸, ACS reagent, ≥98.0%
Sigma-Aldrich
ヨウ化アンモニウム, ACS reagent, ≥99%
Sigma-Aldrich
無水酢酸, 99.5%
Sigma-Aldrich
テストステロン, ≥98%
Sigma-Aldrich
テストステロン, purum, ≥99.0% (HPLC)
Sigma-Aldrich
オキサンドロロン, ≥98% (HPLC)
Supelco
テストステロン 溶液, 1.0 mg/mL in acetonitrile, ampule of 1 mL, certified reference material, Cerilliant®
Supelco
N-メチル-ビス(トリフルオロアセトアミド), derivatization grade (GC derivatization), LiChropur, ≥97.0% (GC)
Sigma-Aldrich
17α-メチルテストステロン, ≥97.0% (HPLC)
Sigma-Aldrich
ヨウ化アンモニウム, 99.999% trace metals basis
Supelco
無水酢酸, derivatization grade (GC derivatization), LiChropur, ≥99.0%
Sigma-Aldrich
17α-メチルテストステロン, solid (photosensitive)
Sigma-Aldrich
無水酢酸
Supelco
2-メルカプトエタノール, derivatization grade (HPLC), LiChropur, ≥99.0% (GC)
Supelco
17α-メチルテストステロン, VETRANAL®, analytical standard
Supelco
N-メチル-ビス(トリフルオロアセトアミド), derivatization grade (GC derivatization), LiChropur, ≥99.0% (GC)
Sigma-Aldrich
無水酢酸, Arxada quality, ≥99.5% (GC)
Supelco
テストステロン, VETRANAL®, analytical standard
Supelco
4-アンドロステン-3,17-ジオン, VETRANAL®, analytical standard
テストステロン, European Pharmacopoeia (EP) Reference Standard
Sigma-Aldrich
2-メルカプトエタノール, ≥99.0%
Sigma-Aldrich
エチステロン, ≥99% (HPLC)
Sigma-Aldrich
2-メルカプトエタノール, SAJ special grade, ≥99.0%
Supelco
17β-Hydroxy-17-methylandrosta-1,4-dien-3-one, analytical standard
Sigma-Aldrich
無水酢酸, JIS special grade