조직 및 계약 가격을 보려면 로그인를 클릭합니다.
크기 선택
제품정보 (DICE 배송 시 비용 별도)
Linear Formula:
[CH2CH(CH2NH2 · HCl)]n
CAS 번호:
NACRES:
NA.23
PubChem Substance ID:
UNSPSC Code:
12162002
EC Number:
415-050-2
MDL number:
form
solid
Quality Level
mol wt
Mw 40,000-150,000
SMILES string
Cl.NCC=C
InChI
1S/C3H7N/c1-2-3-4/h2H,1,3-4H2
InChI key
VVJKKWFAADXIJK-UHFFFAOYSA-N
유사한 제품을 찾으십니까? 방문 제품 비교 안내
Application
Used to make redox hydrogel-modified electrodes for measuring enzyme responses.
Packaging
The polyelectrolyte poly(allylamine hydrochloride) has been used in the preparation of an antireflective coating consisting of alternating layers of poly (allyamine hydrochloride) and silica nanoparticles
Other Notes
May contain up to ≤10% residual monomer.
signalword
Warning
hcodes
Hazard Classifications
Acute Tox. 4 Oral - Skin Sens. 1
저장 등급
11 - Combustible Solids
wgk
WGK 1
ppe
dust mask type N95 (US), Eyeshields, Faceshields, Gloves
Analytical Chemistry, 68, 4186-4186 (1990)
Yancey, S.E. et al
Journal of Applied Physics, 99, 034313-034313 (2006)
Jingguo Li et al.
Chemistry, an Asian journal, 8(2), 385-391 (2012-12-12)
Multimodal imaging and simultaneous therapy is highly desirable because it can provide complementary information from each imaging modality for accurate diagnosis and, at the same time, afford an imaging-guided focused tumor therapy. In this study, indocyanine green (ICG), a near-infrared
Yiyao Liu et al.
Expert opinion on drug delivery, 9(10), 1197-1207 (2012-09-27)
Technologies to increase tissue vascularity are critically important to the fields of tissue engineering and cardiovascular medicine. Angiogenic factors, like VEGF, have been widely investigated to induce vascular endothelial cell proliferation and angiogenesis for establishing a vascular network. However, effective
Ya Wang et al.
Macromolecular bioscience, 12(10), 1321-1325 (2012-09-12)
Fluorescent-magnetic-biotargeting multifunctional microcapsules (FMBMMs) are designed and fabricated via layer-by-layer assembly. It is found that the arginine-glycine-aspartate-modified FMBMMs were capable of sensitively detecting and efficiently isolating approximately 80% target cancer cells within 20 min. More importantly, FMBMMs present a general
문서
Recently, layer-by-layer (LbL) assembly has emerged as a versatile, gentle and, simple method for immobilization of functional molecules in an easily controllable thin film morphology.1,2 In this short review, we introduce recent advances in functional systems fabricated by using the mild, yet adaptable LbL technique.
자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..
고객지원팀으로 연락바랍니다.