1.16754
Water
suitable for UV/Vis spectroscopy, EMSURE®
동의어(들):
DI water, Deionized water
크기 선택
제품정보 (DICE 배송 시 비용 별도)
제품 이름
Water, for analysis EMSURE®
Grade
reagent grade
Quality Level
vapor pressure
23 hPa ( 20 °C)
제품 라인
EMSURE®
양식
liquid
dilution
(for analytical testing)
불순물
≤0.01 mg/L Ammonium (NH4)
≤0.01 mg/L Nitrate (NO3)
≤0.01 mg/L Phosphate (PO4)
≤0.01 mg/L Silicate (SiO2)
≤0.05 mg/L Chloride (Cl)
≤0.05 mg/L Fluoride (F)
≤0.08 mg/L Substances reducing potassium permanganate (O)
≤0.1 mg/L Sulfate (SO4)
증발 잔류물
≤1 mg/L
무기 잔류물
≤1 mg/L
refractive index
n20/D 1.34 (lit.)
pH
7 (20 °C)
bp
100 °C (lit.)
mp
0 °C (lit.)
density
1.000 g/mL at 3.98 °C (lit.)
양이온 미량물
Ag: ≤0.0004 mg/L
Al: ≤0.0020 mg/L
As: ≤0.0020 mg/L
Au: ≤0.0010 mg/L
B: ≤0.0050 mg/L
Ba: ≤0.0010 mg/L
Be: ≤0.0020 mg/L
Bi: ≤0.0010 mg/L
Ca: ≤0.0050 mg/L
Cd: ≤0.0010 mg/L
Co: ≤0.0010 mg/L
Cr: ≤0.0004 mg/L
Cu: ≤0.0004 mg/L
Fe: ≤0.0010 mg/L
Ga: ≤0.0040 mg/L
Ge: ≤0.0010 mg/L
In: ≤0.0010 mg/L
K: ≤0.0050 mg/L
Li: ≤0.0020 mg/L
Mg: ≤0.0050 mg/L
Mn: ≤0.0004 mg/L
Mo: ≤0.0020 mg/L
Na: ≤0.0100 mg/L
Ni: ≤0.0004 mg/L
Pb: ≤0.0010 mg/L
Pd: ≤0.0080 mg/L
Pt: ≤0.0010 mg/L
Sb: ≤0.0010 mg/L
Sn: ≤0.0010 mg/L
Sr: ≤0.0004 mg/L
Ti: ≤0.0010 mg/L
V: ≤0.0010 mg/L
Zn: ≤0.0040 mg/L
Zr: ≤0.0010 mg/L
SMILES string
O
저장 온도
15-25°C
InChI
1S/H2O/h1H2
InChI key
XLYOFNOQVPJJNP-UHFFFAOYSA-N
일반 설명
애플리케이션
- Cadmium Standard for Atomic Absorption Spectroscopy: An article in Heliyon (2024) explores the pollution indices and correlation of heavy metal contamination, including cadmium, in groundwater near industrial sites. This emphasizes the role of cadmium AAS standards in monitoring environmental pollution and ensuring compliance with safety regulations (Mohan et al., 2024).
- Trace Metal Analysis in Food Samples: In a Food Chemistry study (2024), cadmium standards are crucial for the development of novel electrochemical strategies for detecting cadmium in grain and water, using advanced materials like MXene@rGO composite aerogels (Dong et al., 2023).
- Quality Control in Pharmaceutical Research: The need for precise cadmium calibration standards is underlined in another Food Chemistry publication (2024), which discusses simultaneous electrochemical sensing of heavy metals in food, demonstrating their vital role in ensuring the accuracy and reliability of pharmaceutical and biotechnological analyses (Mirzaei Karazan et al., 2024).
기타 정보
법적 정보
Still not finding the right product?
Explore all of our products under Water
Storage Class Code
12 - Non Combustible Liquids
WGK
nwg
Flash Point (°F)
Not applicable
Flash Point (°C)
Not applicable
시험 성적서(COA)
제품의 로트/배치 번호를 입력하여 시험 성적서(COA)을 검색하십시오. 로트 및 배치 번호는 제품 라벨에 있는 ‘로트’ 또는 ‘배치’라는 용어 뒤에서 찾을 수 있습니다.
프로토콜
Photometric determination with Chromazurole S subsequent to acid mineralisation; DIN decomposition
Photometric determination with Chromazurole S subsequent to acid mineralisation
Photometric determination with Chromazurole S subsequent to fusion melting
문서
Application Note: Peroxidase in vegetables – Visual determination after conversion of a specific substrate.
Photometric assessment of bromate in drinking water samples using Spectroquant® photometer and test kits, along with 3,3'-dimethylnaphthidine and potassium iodide.
Preparation of a standard solution for COD/chloride
관련 콘텐츠
AQA Standard for free chlorine - Preparation of a standard solution for free chlorine
국제 무역 품목 번호
| SKU | GTIN |
|---|---|
| 1.16754.5000 | 04022536646343 |
| 1.16754.9010 | 04022536167909 |
| 1.16754.4000 | 04027269032814 |