크기 선택
제품정보 (DICE 배송 시 비용 별도)
InChI key
VZTDIZULWFCMLS-UHFFFAOYSA-N
InChI
1S/CH2O2.H3N/c2-1-3;/h1H,(H,2,3);1H3
SMILES string
N.OC=O
description
anionic
Quality Level
product line
LiChropur™
assay
≥99.0% (calc. on dry substance, NT), ≥99.0%
form
crystals
quality
LiChropur™
technique(s)
LC/MS: suitable
impurities
insoluble matter, passes filter test, <2% water
ign. residue (900°C)
<0.1% (as SO4)
pH
5.5-7.5 (25 °C, 1 M in H2O)
mp
119-121 °C (lit.)
solubility
H2O: 1 M at 20 °C, clear, colorless
density
1.26 g/mL at 25 °C (lit.)
anion traces
chloride (Cl-): ≤50 mg/kg, sulfate (SO42-): ≤50 mg/kg
cation traces
Al: ≤1 mg/kg, As: ≤0.1 mg/kg, Ba: ≤1 mg/kg, Bi: ≤1 mg/kg, Ca: ≤5 mg/kg, Cd: ≤1 mg/kg, Co: ≤1 mg/kg, Cr: ≤1 mg/kg, Cu: ≤1 mg/kg, Fe: ≤1 mg/kg, K: ≤5 mg/kg, Li: ≤1 mg/kg, Mg: ≤1 mg/kg, Mn: ≤1 mg/kg, Mo: ≤1 mg/kg, Na: ≤5 mg/kg, Ni: ≤1 mg/kg, Pb: ≤1 mg/kg, Sr: ≤1 mg/kg, Zn: ≤1 mg/kg
λ
1 M in H2O
UV absorption
λ: 260 nm Amax: ≤0.01, λ: 280 nm Amax: ≤0.01
유사한 제품을 찾으십니까? 방문 제품 비교 안내
General description
Application
Ammonium formate has been used in the separation of non-steroidal anti-inflammatory drugs and of oligosaccharide mixtures using capillary electrochromatography. It is also used in the analysis of phosphatidylserines, triacylglycerols and triacylglycerol oxidation products, and oligogalacturonic acids using HPLC and HPLC-MS methods.
Legal Information
signalword
Warning
hcodes
Hazard Classifications
Eye Irrit. 2
저장 등급
11 - Combustible Solids
flash_point_f
Not applicable
flash_point_c
Not applicable
ppe
dust mask type N95 (US), Eyeshields, Gloves
문서
For use as a marker in SDS-PAGE; Albumin from chicken egg white, For use as a marker in SDS-PAGE; L-Lactic Dehydrogenase from rabbit muscle, Type XI, lyophilized powder, 600-1,200 units/mg protein
2-layer SPE cartridge efficiently reduces background for ginger contaminant analysis.
Pistachios 45% fat complicates pesticide analysis. But Z-Sep+ sorbent cleanup after QuEChERS extraction can reduce background for reliable results.
Ultra-high performance liquid chromatographic (UHPLC) separation of 12 nucleosides using Supel™ Carbon LC column in 15 minutes for use in identification and quantitation of nucleoside biomarkers.
프로토콜
Separation of various acids and compounds by molecular weight: PAA, PEI, PIDADMACl, PAS, cationic dextran, chitosan
Separation of Pyridoxine Hydrochloride (B6), analytical standard; Thiamine Hydrochloride (B1), analytical standard
자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..
고객지원팀으로 연락바랍니다.