Skip to Content
Merck

HT153

Phosphomolybdic Acid Solution

Synonym(s):

Phosphomolybdic acid solution, Molybdophosphoric acid

Sign In to View Organizational & Contract Pricing.

Select a Size

Change View

About This Item

Linear Formula:
H3[P(Mo3O10)4]
CAS Number:
Molecular Weight:
1825.25
NACRES:
NA.47
PubChem Substance ID:
UNSPSC Code:
12352106
MDL number:
Concentration:
10%
Form:
solution
Technical Service
Need help? Our team of experienced scientists is here for you.
Let Us Assist


form

solution

Quality Segment

shelf life

Expiry date on the label

reaction suitability

reagent type: oxidant

IVD

for in vitro diagnostic use

concentration

10%

application(s)

hematology
histology

storage temp.

room temp

SMILES string

O=[Mo](=O)=O.O=[Mo](=O)=O.O=[Mo](=O)=O.O=[Mo](=O)=O.O=[Mo](=O)=O.O=[Mo](=O)=O.O=[Mo](=O)=O.O=[Mo](=O)=O.O=[Mo](=O)=O.O=[Mo](=O)=O.O=[Mo](=O)=O.O=[Mo](=O)=O.OP(O)(O)=O

InChI

1S/12Mo.H3O4P.36O/c;;;;;;;;;;;;1-5(2,3)4;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;/h;;;;;;;;;;;;(H3,1,2,3,4);;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;

InChI key

DHRLEVQXOMLTIM-UHFFFAOYSA-N

Application

Intended for use in the Sigma Masson Trichrome Procedure, HT15.

Preparation Note

Phosphomolydic Acid, 10%. Formation of precipitate does not affect performance in the Masson Trichrome Procedure.


Still not finding the right product?

Explore all of our products under Phosphomolybdic Acid Solution


pictograms

Corrosion

signalword

Danger

hcodes

flash_point_f

Not applicable

flash_point_c

Not applicable

ppe

Faceshields, Gloves, Goggles, type ABEK (EN14387) respirator filter

Hazard Classifications

Eye Dam. 1 - Skin Corr. 1B

Storage Class

8B - Non-combustible corrosive hazardous materials



Choose from one of the most recent versions:

Certificates of Analysis (COA)

Lot/Batch Number

Don't see the Right Version?

If you require a particular version, you can look up a specific certificate by the Lot or Batch number.

Already Own This Product?

Find documentation for the products that you have recently purchased in the Document Library.

Visit the Document Library



Juan Feng et al.
Analytical biochemistry, 409(1), 144-149 (2010-10-26)
The classical malachite green (MLG) assay of phosphate, which added MLG after molybdate to the acidified reaction solutions of phosphate, tolerated interference from papaverine, sildenafil, and some similar hydrophobic amines. Resonance Rayleigh scattering signals, the alleviation of interference by poly(vinyl
Andrey V Bulatov et al.
Talanta, 96, 62-67 (2012-07-24)
Simple, rapid and fully automated methods for the manual and automated spectrophotometric determination of epinephrine have been developed by using schemes of stepwise injection (SWIA) and sequential injection analysis (SIA) implemented in the same manifold. The determination is based on
Paweł K Zarzycki et al.
Analytica chimica acta, 688(2), 168-174 (2011-02-22)
The main goal of present paper is to demonstrate the separation and detection capability of micro-TLC technique involving simple one step liquid extraction protocols of complex materials without multi-steps sample pre-purification. In the present studies target components (cyanobacteria pigments, lipids