콘텐츠로 건너뛰기
Merck

203467

Ammonium iodide

99.999% trace metals basis

동의어(들):

Azanium iodide

조직 및 계약 가격을 보려면 로그인를 클릭합니다.

크기 선택


제품정보 (DICE 배송 시 비용 별도)

Linear Formula:
NH4I
CAS 번호:
Molecular Weight:
144.94
PubChem Substance ID:
eCl@ss:
38050607
UNSPSC Code:
12352302
NACRES:
NA.23
EC Number:
234-717-7
MDL number:
Assay:
99.999% trace metals basis
Form:
crystalline
Solubility:
ethanol: slightly soluble(lit.), methanol: slightly soluble(lit.)
기술 서비스
도움이 필요하신가요? 저희 숙련된 과학자 팀이 도와드리겠습니다.
도움 문의
기술 서비스
도움이 필요하신가요? 저희 숙련된 과학자 팀이 도와드리겠습니다.
도움 문의

InChI key

UKFWSNCTAHXBQN-UHFFFAOYSA-N

InChI

1S/HI.H3N/h1H;1H3

SMILES string

N.I

vapor pressure

1 mmHg ( 210.9 °C)

assay

99.999% trace metals basis

form

crystalline

impurities

≤15.0 ppm Trace Metal Analysis

bp

405 °C/1 atm (lit.)

mp

551 °C (lit.)

solubility

ethanol: slightly soluble(lit.), methanol: slightly soluble(lit.)

Quality Level

유사한 제품을 찾으십니까? 방문 제품 비교 안내

Application

Ammonium iodide can be used as a precursor to prepare polymer electrolytes for dye-sensitized solar cells. It can also be used as a catalyst to synthesize high-purity gallium nitride (GaN) powder.

pictograms

Health hazard

signalword

Danger

hcodes

Hazard Classifications

STOT RE 1 Oral

target_organs

Thyroid

저장 등급

6.1C - Combustible acute toxic Cat.3 / toxic compounds or compounds which causing chronic effects

wgk

WGK 3

flash_point_f

Not applicable

flash_point_c

Not applicable

ppe

dust mask type N95 (US), Eyeshields, Gloves


가장 최신 버전 중 하나를 선택하세요:

시험 성적서(COA)

Lot/Batch Number

적합한 버전을 찾을 수 없으신가요?

특정 버전이 필요한 경우 로트 번호나 배치 번호로 특정 인증서를 찾을 수 있습니다.

이 제품을 이미 가지고 계십니까?

문서 라이브러리에서 최근에 구매한 제품에 대한 문서를 찾아보세요.

문서 라이브러리 방문

Päivi Pöhö et al.
Journal of chromatography. A, 1598, 175-182 (2019-04-21)
A new heated capillary photoionization (CPI) ion source design was developed to photoionize analytes inside a transfer capillary between a gas chromatograph (GC) and a mass spectrometer (MS). The CPI setup included a wide, oval-shaped vacuum-ultraviolet (VUV) transparent magnesium fluoride
Junseok Lee et al.
Chemosphere, 142, 72-76 (2015-06-29)
A novel approach using wavelength dispersive X-ray fluorescence (WDXRF) spectrometry combined with an activated carbon (AC) disk was developed for the determination of total iodine concentrations in water samples. Dissolved iodine species (i.e., I(-) and IO3(-)) in water samples were
Aline C A Silva et al.
Analytical and bioanalytical chemistry, 407(14), 4091-4099 (2015-04-08)
This work evaluates the application of a thermodynamic model to comprehensive two-dimensional gas chromatography (GC × GC) coupled with time-of-flight mass spectrometry for anabolic agent investigation. Doping control deals with hundreds of drugs that are prohibited in sports. Drug discovery
Ebru Uçaktürk
Journal of analytical methods in chemistry, 2015, 707414-707414 (2015-12-19)
A sensitive and selective gas chromatography-mass spectrometry (GC-MS) method was developed and fully validated for the determination of vildagliptin (VIL) in pharmaceutical formulation. Prior to GC-MS analysis, VIL was efficiently derivatized with MSTFA/NH4I/β-mercaptoethanol at 60°C for 30 min. The obtained O-TMS
M Raro et al.
Journal of mass spectrometry : JMS, 49(6), 509-521 (2014-06-11)
The detection of anabolic androgenic steroids (AAS) is one of the most important topics in doping control analysis. Gas chromatography coupled to (tandem) mass spectrometry (GC-MS(/MS)) with electron ionization and liquid chromatography coupled to tandem mass spectrometry have been traditionally

자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..

고객지원팀으로 연락바랍니다.