콘텐츠로 건너뛰기
Merck

551368

1,4-Dioxane solution

suitable for NMR (reference standard), 40% in benzene-d6 (99.6 atom % D)

조직 및 계약 가격을 보려면 로그인를 클릭합니다.

크기 선택

보기 변경

제품정보 (DICE 배송 시 비용 별도)

실험식(Hill 표기법):
C4H8O2
CAS 번호:
Molecular Weight:
88.11
NACRES:
NA.12
PubChem Substance ID:
UNSPSC Code:
12352005
MDL number:
Assay:
99% (CP)
기술 서비스
도움이 필요하신가요? 저희 숙련된 과학자 팀이 도와드리겠습니다.
도움 문의


assay

99% (CP)

Quality Level

concentration

40% in benzene-d6 (99.6 atom % D)

technique(s)

NMR: suitable

NMR tube size

5 mm × 7 in. , 5 mm × 8 in.

suitability

suitable for NMR (reference standard)

SMILES string

C1COCCO1

InChI

1S/C4H8O2/c1-2-6-4-3-5-1/h1-4H2

InChI key

RYHBNJHYFVUHQT-UHFFFAOYSA-N

Features and Benefits

13C sensitivity

Preparation Note

5 mm O.D. tube contains 0.700 mL.


Still not finding the right product?

Explore all of our products under 1,4-Dioxane solution


signalword

Danger

Hazard Classifications

Aquatic Chronic 3 - Asp. Tox. 1 - Carc. 1A - Eye Irrit. 2 - Flam. Liq. 2 - Muta. 1B - Skin Irrit. 2 - STOT RE 1 - STOT SE 3

target_organs

Blood, Respiratory system

supp_hazards

저장 등급

3 - Flammable liquids

wgk

WGK 3

flash_point_f

68.0 °F - closed cup

flash_point_c

20 °C - closed cup

ppe

Eyeshields, Faceshields, Gloves, type ABEK (EN14387) respirator filter



가장 최신 버전 중 하나를 선택하세요:

시험 성적서(COA)

Lot/Batch Number

적합한 버전을 찾을 수 없으신가요?

특정 버전이 필요한 경우 로트 번호나 배치 번호로 특정 인증서를 찾을 수 있습니다.

이 제품을 이미 가지고 계십니까?

문서 라이브러리에서 최근에 구매한 제품에 대한 문서를 찾아보세요.

문서 라이브러리 방문


문서

NMR reference standards ensure proper instrument performance. Review key operational parameters for these standards such as pw90, sensitivity, resolution and line shape.


Kyle T Greenway et al.
The Journal of organic chemistry, 77(20), 9221-9226 (2012-10-03)
Hyperconjugation underlies many chemical phenomena of fundamental and practical importance. Owing to a great deal of interest in the anomeric effect, anomeric-like hyperconjugative effects have been thoroughly investigated in oxygen-containing systems. However, such interactions in the second- and third-row chalcogens
Daniel Gerrity et al.
Water research, 46(19), 6257-6272 (2012-10-16)
The performance of ozonation in wastewater depends on water quality and the ability to form hydroxyl radicals (·OH) to meet disinfection or contaminant transformation objectives. Since there are no on-line methods to assess ozone and ·OH exposure in wastewater, many
A Pan et al.
Langmuir : the ACS journal of surfaces and colloids, 28(39), 13830-13843 (2012-09-07)
Mixed aquo-organic solvents are used in chemical, industrial, and pharmaceutical processes along with amphiphilic materials. Their fundamental studies with reference to bulk and interfacial phenomena are thus considered to be important, but such detailed studies are limited. In this work