์ฝ˜ํ…์ธ ๋กœ ๊ฑด๋„ˆ๋›ฐ๊ธฐ
Merck

81290

Poly(ethylene glycol)

analytical standard, 2,000

๋™์˜์–ด(๋“ค):

PEG

์กฐ์ง ๋ฐ ๊ณ„์•ฝ ๊ฐ€๊ฒฉ์„ ๋ณด๋ ค๋ฉด ๋กœ๊ทธ์ธ๋ฅผ ํด๋ฆญํ•ฉ๋‹ˆ๋‹ค.

ํฌ๊ธฐ ์„ ํƒ

๋ณด๊ธฐ ๋ณ€๊ฒฝ

์ œํ’ˆ์ •๋ณด (DICE ๋ฐฐ์†ก ์‹œ ๋น„์šฉ ๋ณ„๋„)

Linear Formula:
H(OCH2CH2)nOH
CAS ๋ฒˆํ˜ธ:
NACRES:
NA.24
PubChem Substance ID:
UNSPSC Code:
41116107
MDL number:
๊ธฐ์ˆ  ์„œ๋น„์Šค
๋„์›€์ด ํ•„์š”ํ•˜์‹ ๊ฐ€์š”? ์ €ํฌ ์ˆ™๋ จ๋œ ๊ณผํ•™์ž ํŒ€์ด ๋„์™€๋“œ๋ฆฌ๊ฒ ์Šต๋‹ˆ๋‹ค.
๋„์›€ ๋ฌธ์˜


grade

analytical standard

Quality Level

shelf life

limited shelf life, expiry date on the label

mol wt

Mn ~1900, Mp ~2010, Mw ~1960

technique(s)

gel permeation chromatography (GPC): suitable

mp

55-58 ยฐC

Mw/Mn

~1.03

application(s)

cleaning products
cosmetics
food and beverages
personal care

format

neat

storage temp.

2-8ยฐC

InChI

1S/C2H6O2/c3-1-2-4/h3-4H,1-2H2

InChI key

LYCAIKOWRPUZTN-UHFFFAOYSA-N



Still not finding the right product?

Explore all of our products under Poly(ethylene glycol)


์ €์žฅ ๋“ฑ๊ธ‰

11 - Combustible Solids

wgk

WGK 1

flash_point_f

Not applicable

flash_point_c

Not applicable

ppe

Eyeshields, Gloves, type N95 (US)



๊ฐ€์žฅ ์ตœ์‹  ๋ฒ„์ „ ์ค‘ ํ•˜๋‚˜๋ฅผ ์„ ํƒํ•˜์„ธ์š”:

์‹œํ—˜ ์„ฑ์ ์„œ(COA)

Lot/Batch Number

It looks like we've run into a problem, but you can still download Certificates of Analysis from our ๋ฌธ์„œ section.

๋„์›€์ด ํ•„์š”ํ•˜์‹œ๋ฉด ์—ฐ๋ฝํ•˜์„ธ์š”. ๊ณ ๊ฐ ์ง€์› ๋ถ€์„œ

์ด ์ œํ’ˆ์„ ์ด๋ฏธ ๊ฐ€์ง€๊ณ  ๊ณ„์‹ญ๋‹ˆ๊นŒ?

๋ฌธ์„œ ๋ผ์ด๋ธŒ๋Ÿฌ๋ฆฌ์—์„œ ์ตœ๊ทผ์— ๊ตฌ๋งคํ•œ ์ œํ’ˆ์— ๋Œ€ํ•œ ๋ฌธ์„œ๋ฅผ ์ฐพ์•„๋ณด์„ธ์š”.

๋ฌธ์„œ ๋ผ์ด๋ธŒ๋Ÿฌ๋ฆฌ ๋ฐฉ๋ฌธ



Idalis Villanueva et al.
Acta biomaterialia, 5(8), 2832-2846 (2009-06-11)
The pericellular matrix (PCM) surrounding chondrocytes is thought to play an important role in transmitting biochemical and biomechanical signals to the cells, which regulates many cellular functions including tissue homeostasis. To better understand chondrocytes interactions with their PCM, three-dimensional poly(ethylene
Mark A Rice et al.
Acta biomaterialia, 5(1), 152-161 (2008-09-17)
Ultrasound has potential as a non-destructive analytical technique to provide real-time online assessments of matrix evolution in cell-hydrogel constructs used in tissue engineering. In these studies, chondrocytes were encapsulated in poly(ethylene glycol) hydrogels, and gel degradation was manipulated to provide
D D Smyth et al.
Cardiovascular drugs and therapy, 4(1), 297-300 (1990-02-01)
Previous studies have demonstrated that Separan AP-30, a drag-reducing polymer, significantly decreased the formation of atherosclerotic plaques in rabbits fed a high-cholesterol diet. Furthermore, Separan AP-273, a polymer similar to but longer than Separan AP-30, markedly increased cardiac output in