조직 및 계약 가격을 보려면 로그인를 클릭합니다.
크기 선택
제품정보 (DICE 배송 시 비용 별도)
실험식(Hill 표기법):
C4H8O
CAS 번호:
Molecular Weight:
72.11
NACRES:
NB.61
PubChem Substance ID:
UNSPSC Code:
12191501
EC Number:
203-726-8
MDL number:
Beilstein/REAXYS Number:
102391
Assay:
≥99.5% (GC), ≥99.5%
Vapor pressure:
114 mmHg ( 15 °C), 143 mmHg ( 20 °C)
제품 이름
Tetrahydrofuran, Selectophore™, ≥99.5%
Quality Level
vapor pressure
114 mmHg ( 15 °C), 143 mmHg ( 20 °C)
description
for ion-selective electrodes, solvent for preparation of membranes
product line
Selectophore™
assay
≥99.5% (GC), ≥99.5%
form
liquid
autoignition temp.
610 °F
contains
250 ppm BHT as inhibitor
expl. lim.
1.8-11.8 %
impurities
≤0.01% water
mp
−108 °C (lit.)
solubility
H2O: soluble
density
0.889 g/mL at 25 °C (lit.)
유사한 제품을 찾으십니까? 방문 제품 비교 안내
General description
Tetrahydrofuran (THF), an organic compound which belongs to saturated cyclic ether group. It is mainly used as solvent for PVC and organoalkali compounds. It is also used in lithium batteries.
Visit our Sensor Applications portal to learn more.
Application
THF has been used to realise PVC membrane from electrode, during a study to design, fabricate and electrochemically characterize miniaturised thin- and thick-film Ag/AgCl reference electrodes.
Legal Information
Selectophore is a trademark of Merck KGaA, Darmstadt, Germany
signalword
Danger
Hazard Classifications
Acute Tox. 4 Oral - Carc. 2 - Eye Irrit. 2 - Flam. Liq. 2 - STOT SE 3
target_organs
Central nervous system, Respiratory system
supp_hazards
저장 등급
3 - Flammable liquids
wgk
WGK 1
flash_point_f
-6.2 °F - closed cup
flash_point_c
-21.2 °C - closed cup
ppe
Eyeshields, Faceshields, Gloves, type ABEK (EN14387) respirator filter
Strategies of miniaturised reference electrodes integrated in a silicon based ?one chip? pH sensor.
Simonis, Anette, et al.
Sensors, 3.9, 330-339 (2003)
Luca Chiari et al.
The Journal of chemical physics, 138(7), 074301-074301 (2013-03-01)
We present total, elastic, and inelastic cross sections for positron and electron scattering from tetrahydrofuran (THF) in the energy range between 1 and 5000 eV. Total cross sections (TCS), positronium formation cross sections, the summed inelastic integral cross sections (ICS)
P T Clayton et al.
The Journal of clinical investigation, 79(4), 1031-1038 (1987-04-01)
Urinary bile acids from a 3-mo-old boy with cholestatic jaundice were analyzed by ion exchange chromatography and gas chromatography-mass spectrometry (GC-MS). This suggested the presence of labile sulfated cholenoic acids with an allylic hydroxyl group, a conclusion supported by analysis
C N Ong et al.
British journal of industrial medicine, 48(9), 616-621 (1991-09-01)
Occupational exposure to tetrahydrofuran (THF) was studied by analysis of environmental air, blood, alveolar air, and urine from 58 workers in a video tape manufacturing plant. Head space gas chromatography (GC) with an FID detector was used for determination of
Kenneth F Ilett et al.
Drug metabolism and disposition: the biological fate of chemicals, 30(9), 1005-1012 (2002-08-09)
The aim of this study was to elucidate the metabolic pathways for dihydroartemisinin (DHA), the active metabolite of the artemisinin derivative artesunate (ARTS). Urine was collected from 17 Vietnamese adults with falciparum malaria who had received 120 mg of ARTS
자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..
고객지원팀으로 연락바랍니다.