콘텐츠로 건너뛰기
Merck

M1533

N,N′-Methylenebisacrylamide solution

suitable for electrophoresis, 2% in H2O

동의어(들):

BIS

조직 및 계약 가격을 보려면 로그인를 클릭합니다.

크기 선택


제품정보 (DICE 배송 시 비용 별도)

Linear Formula:
(CH2=CHCONH)2CH2
CAS 번호:
Molecular Weight:
154.17
UNSPSC Code:
41105319
NACRES:
NB.22
PubChem Substance ID:
MDL number:
Beilstein/REAXYS Number:
1706297
기술 서비스
도움이 필요하신가요? 저희 숙련된 과학자 팀이 도와드리겠습니다.
도움 문의
기술 서비스
도움이 필요하신가요? 저희 숙련된 과학자 팀이 도와드리겠습니다.
도움 문의

sterility

0.2 μm filtered

Quality Level

form

liquid

concentration

2% in H2O

technique(s)

electrophoresis: suitable

storage temp.

2-8°C

SMILES string

C=CC(=O)NCNC(=O)C=C

InChI

1S/C7H10N2O2/c1-3-6(10)8-5-9-7(11)4-2/h3-4H,1-2,5H2,(H,8,10)(H,9,11)

InChI key

ZIUHHBKFKCYYJD-UHFFFAOYSA-N

General description

N,N′-Methylenebisacrylamide solution is a cross-linking agent used in polyacrylamide gel preparation.

Application

N,N′-Methylenebisacrylamide solution has been used as a component of hydrogel precursor solution and magnified analysis of the proteome (MAP) gel solution during hydrogel fabrication. It has also been used as a component of re-embedding solution during re-embedding of expanded hydrogels.
To be mixed with acrylamide for making polyacrylamide gels for use in protein and nucleic acid electrophoresis.

Preparation Note

Prepared from electrophoresis grade bis-acrylamide in ultra-pure water.

pictograms

Health hazard

signalword

Danger

Hazard Classifications

Carc. 1B - Muta. 1B - STOT RE 2 Oral

target_organs

Peripheral nervous system

저장 등급

6.1D - Non-combustible acute toxic Cat.3 / toxic hazardous materials or hazardous materials causing chronic effects

wgk

WGK 3

flash_point_f

Not applicable

flash_point_c

Not applicable

ppe

Eyeshields, Faceshields, Gloves, multi-purpose combination respirator cartridge (US)


가장 최신 버전 중 하나를 선택하세요:

시험 성적서(COA)

Lot/Batch Number

적합한 버전을 찾을 수 없으신가요?

특정 버전이 필요한 경우 로트 번호나 배치 번호로 특정 인증서를 찾을 수 있습니다.

이 제품을 이미 가지고 계십니까?

문서 라이브러리에서 최근에 구매한 제품에 대한 문서를 찾아보세요.

문서 라이브러리 방문

A J Aho et al.
British journal of anaesthesia, 115(2), 258-266 (2015-07-04)
Concomitantly recorded Bispectral Index® (BIS) and Entropy™ values sometimes show discordant trends during general anaesthesia. Previously, no attempt had been made to discover which EEG characteristics cause discrepancies between BIS and Entropy. We compared BIS and Entropy values, and analysed
Bjørn Bjorvatn et al.
Sleep & breathing = Schlaf & Atmung, 19(4), 1387-1393 (2015-04-10)
The objective of the present study was to investigate the prevalence of insomnia and excessive sleepiness in relation to the presence and severity of obstructive sleep apnea (OSA). The sample consisted of patients referred to a university hospital on suspicion
Jean Guglielminotti et al.
Anesthesiology, 122(5), 985-993 (2015-03-03)
Individual assessment of the amplitude of a physiologic reflex evoked by a standardized noxious test (SNT) before surgical stimulation has been suggested to predict movement upon the forthcoming surgical stimulation. This study aimed to compare the ability of pupillary dilatation
Yan Lu et al.
ACS nano, 4(12), 7078-7086 (2010-11-19)
Here, we demonstrate that bimetallic Au-Pt nanorods (NRs) can be grown in situ into thermosensitive core-shell microgel particles by a novel two-step approach. In the first step, Au NRs with an average width of 6.6 ± 0.3 nm and length
David R Kryscio et al.
Analytica chimica acta, 718, 109-115 (2012-02-07)
Molecularly imprinted polymers are synthetic antibody mimics formed by the crosslinking of organic or inorganic polymers in the presence of an analyte which yields recognitive polymer networks with specific binding pockets for that biomolecule. Surface imprinted polymers were synthesized via

관련 콘텐츠

자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..

고객지원팀으로 연락바랍니다.